Tools
-
-
Gather all components. Click Here for exploded view and parts list.
-
-
-
-
-
-
Use the 1-1/8" deep socket to Install Vertical Shaft 75-1854 to Elbow 75-1860S. Torque to 20 ft-lbs.
-
Keep the nozzle carriers 90 degrees offset from each other. One carrier should be at 6 and 12 while the other remains at 3 and 9 O' clock.
-
After tightening the vertical shaft to 20 Ft-lbs, check that the gears are properly meshing by spinning the nozzle carriers.
-
Apply a small amount of anti-seize to the 75-1801-SS Rotor and snugly tighten to the 75-1854 Vertical Shaft by using a flat wrench.
-
-
-
Install Rotor 75-1801-SS to Vertical Shaft 75-1854 using a flat wrench.
-
Apply anti-seize to rotor.
-
Tighten snugly.
-
-
-
-
The Hygienic 4 is complete!
-
Each Hygienic 4 comes with a bypass plug kit.
-
Cancel: I did not complete this guide.
One other person completed this guide.